Indonesia Conference Directory


<< Back

METHOD VALIDATION FOR NITRATE ANALYSIS IN WATER USING SPECTROPHOTOMETER Visible WITH CADMIUM REDUCTION
Willy Cahya Nugraha(a*) ,Yohanes Susanto Ridwan(b)

(a,b) Research Unit for Clean Technology,
Indonesian Institute of Sciences
Jl. Cisitu Sangkuriang, Bandung 40135
Telp/Fax : (022) 2503051/(022) 2503240
*E-mail : will003[at]lipi.go.id


Abstract

Nitrate is one of pollutants which is found in water and dangerous for human health. Spectrophotometer UV Vis method using cadmium reduction is a simple method and cheap but it has a difficult technique and can be used for nitrate analysis. The method was validate according with analytical parameters. The result of this study were linear range 0.069- 5 mg.L- 1, limit detection and quantitation were 0.025 mg.L-1 and 0.069 mg.L-1, respectively. repeatibility of the method 2.19 % rsd and accuracy with 102.7 % recovery. All of parameters have a good performance and can be used for nitrate analysis for water sample.

Keywords: water, nitrate, spektofotometer UV Visible, validate

Topic: Chemistry

Link: https://ifory.id/abstract/3QgPpzLyjuAY

Conference: The 4th Annual Applied Science and Engineering Conference (AASEC 2019)

Plain Format | Corresponding Author (Willy Cahya Nugraha)