Failure Analysis of Tube Reboiler Sour Water Stripper Heat Exchanger in Refinery Industry
Moch Ardi Dimastiar (a), Lutfy Faluthi Firdaus (a), Johny Wahyuadi (a), Ahmad Taufik (b), Edi Kunedi (b)

a) Metallurgy and Material Department, University of Indonesia
Depok 16424, Jawa Barat, Indonesia
b) AT Solusi Ltd.
Jakarta Selatan 12240, DKI Jakarta, Indonesia


Abstract

Heat exchanger is a device which is used to transfer heat from one medium to another. When the tubes fail, the reliability of heat exchanger is affected. This paper investigates the probable causes of failure of the tube reboiler sour water stripper in a heat exchanger. In that context, visual observation, dimensional measurement, mechanical testing, metallographic examination, and chemical analysis are conducted as part of the investigative studies. Finally, it has been concluded that the tube has mainly failed due to sulphide stress corrosion cracking.

Keywords: Failure Analysis; Heat Exchanger; Tube Bundle; Stress Corrosion Cracking